526 research outputs found

    Beam Loss Monitors at LHC

    Full text link
    One of the main functions of the LHC beam loss measurement system is the protection of equipment against damage caused by impacting particles creating secondary showers and their energy dissipation in the matter. Reliability requirements are scaled according to the acceptable consequences and the frequency of particle impact events on equipment. Increasing reliability often leads to more complex systems. The downside of complexity is a reduction of availability; therefore, an optimum has to be found for these conflicting requirements. A detailed review of selected concepts and solutions for the LHC system will be given to show approaches used in various parts of the system from the sensors, signal processing, and software implementations to the requirements for operation and documentation.Comment: 16 pages, contribution to the 2014 Joint International Accelerator School: Beam Loss and Accelerator Protection, Newport Beach, CA, USA , 5-14 Nov 201

    Commissioning of Beam Loss Monitors

    Get PDF

    Modelling of Quench Limit for Steady State Heat Deposits in LHC Magnets

    Get PDF
    A quench, the transition of a conductor from the superconducting to the normal conducting state, occurs irreversibly in the accelerator magnets if one of the three parameters: temperature, magnetic field or current density exceeds a critical value. Energy deposited in the superconductor by the particle beams provokes quenches detrimental for the accelerator operation. In particular if particles impacting on the vacuum chamber and their secondary showers depose energy in the magnet coils. The Large Hadron Collider (LHC) nominal beam intensity is 3.2 ldr 10^14 protons. A quench occurs if a fraction of the order of 10^7 protons per second is lost locally. A network model is used to simulate the thermodynamic behaviour of the magnets. The heat flow in the network model was validated with measurements performed in the CERN magnet test facility. A steady state heat flow was introduced in the coil by using the quench heaters implemented in the LHC magnets. The value of the heat source current is determined by the network model and the magnet coil current which is required to quench the coil is predicted accordantly. The measured and predicted value comparison is regarded as a sensitive test of the method

    Secondary Electron Emission Beam Loss Monitor for LHC

    Get PDF
    Beam Loss Monitoring (BLM) system is a vital part of the active protection of the LHC accelerators' elements. It should provide the number of particles lost from the primary hadron beam by measuring the radiation field induced by their interaction with matter surrounding the beam pipe. The LHC BLM system will use ionization chambers as standard detectors but in the areas where very high dose rates are expected, the Secondary Emission Monitor (SEM) chambers will be employed because of their high linearity, low sensitivity and fast response. The SEM needs a high vacuum for proper operation and has to be functional for up to 20 years, therefore all the components were designed according to the UHV requirements and a getter pump was included. The SEM electrodes are made of Ti because of its Secondary Emission Yield (SEY) stability. The sensitivity of the SEM was modeled in Geant4 via the Photo-Absorption Ionization module together with custom parameterization of the very low energy secondary electron production. The prototypes were calibrated by proton beams in CERN PS Booster dump line, SPS transfer line and in PSI Optis line. The results were compared to the simulations

    An FPGA Based Implementation for Real-Time Processing of the LHC Beam Loss Monitoring System's Data

    Get PDF
    The strategy for machine protection and quench prevention of the Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is mainly based on the Beam Loss Monitoring (BLM) system. At each turn, there will be several thousands of data to record and process in order to decide if the beams should be permitted to continue circulating or their safe extraction is necessary to be triggered. The processing involves a proper analysis of the loss pattern in time and for the decision the energy of the beam needs to be accounted. This complexity needs to be minimized by all means to maximize the reliability of the BLM system and allow a feasible implementation. In this paper, a field programmable gate array (FPGA) based implementation is explored for the real-time processing of the LHC BLM data. It gives emphasis on the highly efficient Successive Running Sums (SRS) technique used that allows many and long integration periods to be maintained for each detector's data with relatively small length shift registers that can be built around the embedded memory blocks

    Classification of the LHC BLM Ionization Chamber

    Get PDF
    The LHC beam loss monitoring (BLM) system must prevent the super conducting magnets from quenching and protect the machine components from damage. The main monitor type is an ionization chamber. About 4000 of them will be installed around the ring. The lost beam particles initiate hadronic showers through the magnets and other machine components. These shower particles are measured by the monitors installed on the outside of the accelerator equipment. For the calibration of the BLM system the signal response of the ionization chamber is simulated in GEANT4 for all relevant particle types and energies (keV to TeV range). For validation, the simulations are compared to measurements using protons, neutrons, photons and mixed radiation fields at various energies and intensities. This paper will focus on the signal response of the ionization chamber to various particle types and energies including space charge effects at high ionization densities

    The LHC Beam Loss Monitoring System's Surface Building Installation

    Get PDF
    The strategy for machine protection and quench prevention of the Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is mainly based on the Beam Loss Monitoring (BLM) system. At each turn, there will be several thousands of data to record and process in order to decide if the beams should be permitted to continue circulating or their safe extraction is necessary. The BLM system can be sub-divided geographically to the tunnel and the surface building installations. In this paper the surface installation is explored, focusing not only to the parts used for the processing of the BLM data and the generation of the beam abort triggers, but also to the interconnections made with various other systems in order to provide the needed functionality

    Functional and Linearity test system for the LHC Beam Loss Monitoring data acquisition card

    Get PDF
    In the frame of the design and development of the beam loss monitoring (BLM) system for the Large Hadron Collider (LHC) a flexible test system has been developed to qualify and verify during design and production the BLM LHC data acquisition card. It permits to test completely the functionalities of the board as well as realizing analog input signal generation to the acquisition card. The system utilize two optical receivers, a Field Programmable Gate Array (FPGA), eights flexible current sources and a Universal Serial Bus (USB) to link it to a PC where a software written in LabWindows/CVI© (National Instruments) runs. It includes an important part of the measurement processing developed for the BLM in the future LHC accelerator. It is called Beam Loss Electronic Current to Frequency Tester (BLECFT)

    Single Gain Radiation Tolerant LHC Beam Loss Acquisition Card

    Get PDF
    The beam loss monitoring system is one of the most critical elements for the protection of the LHC. It must prevent the super conducting magnets from quenches and the machine components from damages, caused by beam losses. Ionization chambers and secondary emission based detectors are used at several locations around the ring. The sensors are producing a signal current, which is related to the losses. This current will be measured by a tunnel card, which acquires, digitizes and transmits the data via an optical link to the surface electronic. The usage of the system, for protection and tuning of the LHC and the scale of the LHC, imposed exceptional specifications of the dynamic range and radiation tolerance. The input dynamic allows measurements between 10pA and 1mA and its protected to high pulse of 1.5kV and its corresponding current. To cover this range, a current to frequency converter in combination with an ADC is used. The integrator output voltage is measured with an ADC to improve the resolution. The radiation tolerance required the adaption of conceptional design and a stringent selection of the components
    • …
    corecore